Ampio CAN modules tag


M-ALARM-8s: Alarm control panel with eight alarm inputs

Module M-ALARM-8s is a component of the Ampio system. Required voltage to power the module is 18 — 24V DC. The module is controlled via CAN bus. The M-ALARM-8s module has the functionality of a control panel, with eight alarm inputs, two power outputs and six binary OC outputs.

Last update April 28, 2025, tags: Ampio CAN modules, ALARM family, DIN rail modules, Security, Access control

M-SERV-3s: Remote system management and IP integrations module Discontinued

Module M-SERV-3s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-3s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - plus, it enables IP integrations.

Last update April 22, 2025, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, LoRa

M-CON-WL-p: Ampio LoRa base station module

Module M-CON-WL-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as a base station for wireless modules that communicate using the Ampio LoRa technology

Last update April 22, 2025, tags: Ampio CAN modules, CON family, Junction box modules, LoRa

M-OC-4s: Module with four OC outputs and an RGBW controller functionality MRGBWOC-4s

Module M-OC-4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four OC outputs and supports the functionality of an RGBW lighting controller.

Last update April 8, 2025, tags: CCT, Ampio CAN modules, OC family, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-INOC-4p: Module with four bi-state inputs, four OC outputs and an RGBW controller functionality MRGBWOC-4p

Module M-INOC-4p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four ground-detecting inputs, four OC outputs, and a 1-Wire interface. It also supports the functionality of the RGBW lighting controller.

Last update April 8, 2025, tags: CCT, Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Junction box modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating

M-OC-C8s: Module with eight OC outputs and an RGBW controller functionality

Module M-OC-C8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight OC outputs, four ground-detecting inputs and supports the functionality of an RGBW lighting controller.

Last update April 8, 2025, tags: CCT, Ampio CAN modules, OC family, Integrations, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating, Security, Wall switch

M-INOC-8s: Module with eight bi-state inputs and eight OC outputs

Module M-INOC-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight ground-detecting inputs, eight OC outputs, and a 1-Wire interface.

Last update April 8, 2025, tags: CCT, Ampio CAN modules, IN family, OC family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, DIN rail modules, Lights, LED lights, Open-collector drivers, Central heating

M-CON-DL-s: DALI bus Integration module MDALI-1s, M-CON-DALI-s

Module M-CON-DL-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module is intended for integration with lighting with a Dali interface. Dali is the main lighting used in industrial halls, large-format supermarkets and with the ongoing rapid development of automation systems, also in residential buildings.

Last update April 8, 2025, tags: CCT, Ampio CAN modules, CON family, Output modules, DIN rail modules, Lights, Dimmer, Dali, Integrations, LED lights, RGBW lights

M-DOT-T6: 6-field touchscreen panel module

Module M-DOT-T6 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has six touch-sensitive fields and a configurable touch display, as well as a 1-Wire interface.

Last update March 20, 2025, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Display, Data visualisation, Wall switch, Touch panels, Personalisation, Access control

M-CON-KNX-s: KNX integration module MKNX-1s

Module M-CON-KNX-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module enables two-way communication between devices operating within the CAN and KNX bus.

Last update March 14, 2025, tags: Ampio CAN modules, CON family, DIN rail modules, Lights, Dimmer, KNX, Integrations