Sensors tag


M-DOT-15: 15-fields touch panel module with display Discontinued

Module M-DOT-15 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has fifteen sensor fields, a display and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update April 15, 2024, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Display, Input modules, Wall switch, Touch panels, Personalisation

M-CON-232-s: RS-232 integration module

Module M-CON-232-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for the integration of devices equipped with an RS-232 communication interface with the Ampio home automation system.

Last update March 21, 2024, tags: Ampio CAN modules, CON family, Sensors, SATEL, Security, DIN rail modules, Integrations, RS-232, Air conditioning, Weather station

M-IN-2p: Module with two bi-state inputs

Module M-IN-2p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has two ground detecting inputs, a 1-Wire interface and a brightness sensor.

Last update November 2, 2023, tags: Ampio CAN modules, IN family, Junction box modules, Wall switch, Sensors, Input modules, Dallas 18B20

M-IN-TCD3p: Module with three NTC sensor inputs

Module M-IN-TCD3p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has three inputs for NTC temperature sensors with a resistance within the range of 5-20kΩ at 25°C.

Last update October 27, 2023, tags: Ampio CAN modules, IN family, Sensors, Input modules, Central heating, Junction box modules

M-CON-ZWAVE-s: Z-Wave integration module MZWAVE-1s

Module M-CON-ZWAVE-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for integration with a number of devices that support the Z-Wave wireless communication protocol.

Last update September 26, 2023, tags: Ampio CAN modules, CON family, Sensors, Wall switch, Central heating, DIN rail modules, Integrations

M-DOT-9: 9-fields touch panel module

Module M-DOT-9 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has nine sensor fields and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update March 7, 2023, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Wall switch, Touch panels, Personalisation

M-IN-PTK3p: Module with three PT1000 sensor inputs MPT-3p Discontinued

Module M-IN-PTK3p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has three platinum PT1000 temperature sensors inputs. PT1000 inputs The module has inputs that allow for measuring the temperature with the use of platinum PT1000 sensors.

Last update July 7, 2022, tags: Ampio CAN modules, IN family, Sensors, Input modules, Central heating, Junction box modules

M-SENS-LITE: Ambient conditions measuring module MSENS-1

Module M-SENS-LITE is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module allows for the measurement of ambient conditions in closed spaces. Measurement of ambient conditions The module facilitates measuring a number of parameters for the environmental conditions present in closed spaces.

Last update April 5, 2022, tags: Ampio CAN modules, SENS family, Input modules, Sensors, Personalisation

M-METEO: Weather station Discontinued

Module M-METEO is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. It is controlled via the RS-485 interface using the Modbus RTU protocol. Each M-METEO weather station comes with an M-CON-485 module, which enables the device to work with the CAN bus of Ampio building automation system.

Last update February 23, 2022, tags: Ampio CAN modules, METEO family, Input modules, Sensors, Weather station, RS-485, Modbus